Your Position:Home>News>Company news>Maintenance and service about diesel generators and gas generators

Maintenance and service about diesel generators and gas generators

Date:2019-06-06

The main maintenance content due to the generation of generating units and the use of different conditions. Should be carried out as appropriate to the operation of routine maintenance:

Check whether the rotating coupling bolts are loose. Lack of time in time to tighten; 2 check the oil pan in the oil pan .......

 

Maintenance of generator sets

The main maintenance content due to the generation of generating units and the use of different conditions. Should be carried out as appropriate to the operation of routine maintenance:

1 Check if the coupling bolts are loose. Lack of timely tightening; 2 check the oil pan in the oil pan. Should check the inlet and outlet pipes and cylinder gasket seal; remove the appearance of grease and dust, adhere to the room clean and tidy; 3 check the oil tank;

 

First level technical maintenance:

1,50-80 hours, the daily maintenance of the contents of the increase; if necessary, replace the clean air filter.

2, replace the diesel filter, air filter, water filter;

3, check the tension level of the transmission belt;

4, for all the oil filler, lubricating parts plus lubricating oil;

5, replace the cooling water

 

Secondary technical maintenance: 250-300 hours) daily maintenance and maintenance of the contents of the increase

1, cleaning piston, piston pin, cylinder liner, piston ring, connecting rod bearings and check the wear and tear;

2, check the rolling main bearing inner and outer ring is not loose phenomenon;

3, remove the cooling water system water within the scale, sediment;

4, remove the cylinder combustion chamber and into the exhaust channel of carbon deposition;

5, to adjust the grinding; check the valve, valve seat, putter and rocker with wear and tear.

6, cleaning turbocharger rotor carbon deposition. If necessary;

Found that the problem should be changed. Check the generator and diesel coupler bolts are loose, sliding teeth.

 

Three technical support: 500-1000 hours

Daily maintenance, first-class maintenance, secondary maintenance of the contents of the increase

1, check the adjustment of fuel injection angle;

2, cleaning fuel tank;

3, cleaning the oil pan;

4, check the fuel injection nozzle atomization.